Analysis of Solar Still Combined with Heat Pump

second prototype

 This work concerns a second prototype of solar still combined with a heat pump HP. It is characterized by having separated by a partition, the steam generator compartment of the HP from the compartment evaporator (where the condensate is collected).

The results of the test measures concern three configurations with HP according to whether the distiller is fixed to the south or constantly oriented to the sun and it is placed outside (in the sun) or inside (no sun).

The measurements concerning the water temperatures at the condenser, the wet and ambient air, and the relative humidity.